PRODUCT DETAILS
DESIGN
Conductor material
bare copper strand
Conductor class
acc. to DIN VDE 0295 class 6 resp. IEC 60228 cl. 6
Core insulation
special thermoplastic compound
Core identification
acc. to VDE 0293 black with white numerals with GNYE, 3 x (2 x 0,5) DIN 47100
Stranding
stranded in pairs, cores stranded in layers
Inner sheath material
Overall shield
tinned copper braid, coverage approx. 85 %
Outer sheath material
PUR
Sheath colour
black, RAL 9005
ELECTRICAL PROPERTIES
Rated voltage AC IEC
> 0,5 mm² = 300 V; > 1,0 mm² = Uo/U 300/500 V
Testing voltage
Conductor resistance
Insulation resistance
Current carrying capacity
acc. to DIN VDE, see Technical Guideline
MECHANICAL & DYNAMIC PROPERTIES
Min. bending radius fixed
15 x d
Min. bending radius moved
15 x d
Traverse length (m) - drag chain
Traverse speed (m/s) - drag chain
Acceleration (m/s²) - drag chain
Bending cycles (mln)
THERMAL PROPERTIES
Operat. temp. fixed min./max. [°C]
-30 °C / +70 °C
Operat. temp. moved min/max [°C]
-30 °C / +70 °C
Temp. at conductor in operation max [°C]
STANDARDS & APPROVALS